Description
Manufacturer: ABB
Model: NFZ22E-21
Condition: Used. Comes in non-original packaging. These relays are in good condition with minor scuffs and scratches from previous use.
Cosmetic appearance may vary slightly from pictured unit(s).
Notes: These relays were removed from working equipment and have not been tested since their removal.
No manuals, cords/cables, or additional items are included if not listed or shown.
Included:
- (3) ABB NFZ22E-21 Relay 24-60V 50/60Hz
- (3) ABB CA4-40U Auxiliary Contact
Specifications:
- Manufacturer: ABB
- Model: NFZ22E-21
-
Description: Relay
- Number of Auxiliary Contacts NO: 2
- Number of Auxiliary Contacts NC: 2
- Rated Operational Voltage: Auxiliary Circuit 690 V
-
Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
- Control Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, Θ = 40 °C 16 A
-
Rated Operational Current AC-15 (Ie):
- (500 V) 2 A
- (690 V) 2 A
- (24 / 127 V) 6 A
- (220 / 240 V) 4 A
- (400 / 440 V) 3 A
-
Rated Short-time Withstand Current Low Voltage (Icw):
- for 0.1 s 140 A
- for 1 s 100 A
-
Maximum Electrical Switching Frequency:
- (AC-15) 1200 cycles per hour
- (DC-13) 900 cycles per hour
-
Rated Operational Current DC-13 (Ie):
- (24 V) 6 A / 144 W
- (48 V) 2.8 A / 134 W
- (72 V) 1 A / 72 W
- (110 V) 0.55 A / 60 W
- (125 V) 0.55 A / 69 W
- (220 V) 0.27 A / 60 W
- (250 V) 0.27 A / 68 W
- (400 V) 0.15 A / 60 W
- (500 V) 0.13 A / 65 W
- (600 V) 0.1 A / 60 W
- Rated Impulse Withstand Voltage (Uimp): 6 kV
- Manufacturer: ABB
- Model: CA4-40U
- Description: Auxiliary Contact
- Number of Auxiliary Contacts NO: 4
- Rated Operational Voltage: Auxiliary Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, Θ = 40 °C 16 A
-
Rated Operational Current AC-15 (Ie):
- (500 V) 2 A
- (690 V) 2 A
- (24 / 127 V) 6 A
- (220 / 240 V) 4 A
- (400 / 440 V) 3 A
-
Rated Short-time Withstand Current Low Voltage (Icw):
- for 0.1 s 140 A
- for 1 s 100 A
-
Maximum Electrical Switching Frequency:
- (AC-15) 1200 cycles per hour
- (DC-13) 900 cycles per hour
-
Rated Operational Current DC-13 (Ie):
- (24 V) 6 A / 144 W
- (48 V) 2.8 A / 134 W
- (72 V) 1 A / 72 W
- (110 V) 0.55 A / 60 W
- (125 V) 0.55 A / 69 W
- (220 V) 0.27 A / 60 W
- (250 V) 0.27 A / 68 W
- (400 V) 0.15 A / 60 W
- (500 V) 0.13 A / 65 W
- (600 V) 0.1 A / 60 W
-
Rated Insulation Voltage (Ui):
- acc. to IEC 60947-5-1 690 V
- acc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp): 6 kV