Beckhoff BK5250 DeviceNet Coupler w/ KL1184, KM1002-0000, KL9400, KL2012, ECT.

SKU:
X41S001
Shipping:
Calculated at Checkout
  • Beckhoff BK5250 DeviceNet Coupler w/ KL1184, KM1002-0000, KL9400, KL2012, ECT.
  • Beckhoff BK5250 DeviceNet Coupler w/ KL1184, KM1002-0000, KL9400, KL2012, ECT.
  • Beckhoff BK5250 DeviceNet Coupler w/ KL1184, KM1002-0000, KL9400, KL2012, ECT.
  • Beckhoff BK5250 DeviceNet Coupler w/ KL1184, KM1002-0000, KL9400, KL2012, ECT.
  • Beckhoff BK5250 DeviceNet Coupler w/ KL1184, KM1002-0000, KL9400, KL2012, ECT.
$599.99

Description

Manufacturer: Beckhoff

Model: BK5250

Condition: Used. Comes in non-original packaging. This ethernet coupler is in good condition with minor scuffs and scratches from previous use.
The photos show the exact item(s) the buyer will receive.

Notes: This ethernet coupler was removed from a working system and has not been tested since its removal.
No manuals, cords/cables, or additional items are included if not listed or shown.

Included:

  • (1) Beckhoff BK5250 DeviceNet Coupler
  • (1) Beckhoff KL1184 Digital Input Module 4x Digital Input 24VDC Negative Switch 3ms
  • (4) Beckhoff KM1002-0000 Digital Input Terminals Module
  • (2) Beckhoff KL9400 PLC module
  • (5) Beckhoff KL2012 2 x digital output
  • (4) Beckhoff KL2622 PLC module
  • (1) Beckhoff KL1408 Digital Input Terminal 8-Channel
  • (1) Beckhoff KL2408 Digital Output Terminal 8-Channel
  • (1) Beckhoff KL9010 Bus End Terminal

Specifications:

  • Manufacturer: Keckhoff
  • Model: BK5250
    • Number of Bus Terminals 64 (255 with K-bus extension)
    • Max. number of bytes Fieldbus 512 byte input and 512 byte output
    • Digital peripheral signals 1,020 inputs/outputs
    • Analog peripheral signals 256 inputs/outputs
    • Configuration possibility via KS2000 or the controller
    • Data transfer rates automatic detection
    • Bus interface 1 x open pluggable connector, 5-pin, included
    • Data transfer medium screened, twisted copper wire with power supply, 5-pin
    • Power supply 24 V DC (-15 %/+20 %), through bus cable 11…25 V (conforms to DeviceNet specification)
  • Model: KL1184
    • Connection technology 2-/3-wire
    • Specification ground switching
    • Number of inputs 4
    • Nominal voltage 24 V DC (-15 %/+20 %)
    • “0” signal voltage 18…30 V
    • “1” signal voltage 0…7 V
    • Input filter type. 3.0 ms
    • Input current type. 5 mA
    • Current consumption K-bus typ. 8 mA
    • Electrical isolation 500 V (K-bus/field potential)
    • Bit width in the process image 4 inputs
    • Configuration no address or configuration setting
  • Model: KM1002
    • Connection technology plug
    • Specification EN 61131-2, type 1
    • Number of inputs 16 (2 x 8)
    • Nominal voltage 24 V DC (-15 %/+20 %)
    • “0” signal voltage -3…+5 V
    • “1” signal voltage 15…30 V
    • Input filter type. 3.0 ms
    • Input current type. 5 mA
    • Current consumption K-bus Typ. 3 mA
    • Current consumption power contacts – (no power contacts)
    • Electrical isolation 500 V (K-bus/field potential)
    • Bit width in the process image 16 inputs
    • Configuration no address or configuration setting
  • Model: KL9400
    • Input voltage 24 V DC (-15 %/+20 %)
    • Output voltage 5 V DC
    • Output current 2 A for K-bus supply
    • Power contacts max. 24 V DC/max. 10 A
    • Short-circuit proof yes
  • Model: KL2012
    • Connection technology 4-wire
    • Number of outputs 2
    • Nominal voltage 24 V DC (-15 %/+20 %)
    • Load type ohmic, inductive, lamp load
    • Max. output current 0.5 A (short-circuit proof) per channel
    • Short-circuit current < 2 A
    • Breaking energy < 150 mJ/channel
    • Reverse voltage protection –
    • Electrical isolation 500 V (K-bus/field potential)
    • Current consumption power contacts type. 15 mA + load
    • Current consumption K-bus typ. 5 mA
    • Bit width in the process image 2 outputs
    • Configuration no address or configuration setting
  • Model: KL2622
    • Number of outputs 2 x make contacts
    • Nominal voltage 230 V AC/30 V DC
    • Load type ohmic, inductive, lamp load
    • Max. output current 5 A per channel
    • Switching current 5 A AC/DC (ohmic)/2 A AC/DC (inductive)
    • Ohmic switching current 5 A AC/DC
    • Inductive switching current 2 A AC/DC
    • Minimum permitted load 10 mA at 5 V DC
    • Lamp test, electronic ballast max. 5 A starting current (4 x 58 W)
    • Electrical isolation 500 V (K-bus/field potential)
    • Current consumption power contacts –
    • Current consumption K-bus Typ. 85 mA
    • Bit width in the process image 2 outputs
    • Operating cycles mech. (min.) 2 x 107
    • Operating cycles are electric. (min.) 1 x 105 (5 A/30 V DC)
    • Configuration no address or configuration setting
    • Special features potential-free contacts
  • Model: KL1408
    • Connection technology 1-wire
    • Specification EN 61131-2, type 1/3
    • Number of inputs 8
    • Nominal voltage 24 V DC (-15 %/+20 %)
    • “0” signal voltage -3…+5 V (EN 61131-2, type 1/3)
    • “1” signal voltage 11…30 V (EN 61131-2, type 3)
    • Input filter type. 3.0 ms
    • Input current type. 3 mA (EN 61131-2, type 3)
    • Current consumption K-bus typ. 5 mA
    • Current consumption power contacts typ. 2 mA + load
    • Electrical isolation 500 V (K-bus/field potential)
    • Bit width in the process image 8 inputs
    • Configuration no address or configuration setting
  • Model: KL2408
    • Connection technology 1-wire
    • Number of outputs 8
    • Nominal voltage 24 V DC (-15 %/+20 %)
    • Load type ohmic, inductive, lamp load
    • Max. output current 0.5 A (short-circuit proof) per channel
    • Short-circuit current < 2 A
    • Breaking energy < 150 mJ/channel
    • Reverse voltage protection yes
    • Electrical isolation 500 V (K-bus/field potential)
    • Current consumption power contacts type. 60 mA + load
    • Current consumption K-bus Typ. 18 mA
    • Bit width in the process image 8 outputs
    • Configuration no address or configuration setting
  • Model: KL9010
    • Special features end terminal for bus communication


Hassle Free Returns

  • DougDeals will pay return shipping if the item needs to be returned for any reason
  • Return window is 30 days from delivery date
  • See complete terms

CDN Systems LLC, DBA Doug Deals, is not an authorized distributor or affiliated with the manufacturer of this product. Original manufacturer's warranty does not apply.

View AllClose

Additional Information

Condition:
Used