Description
Manufacturer: Beckhoff
Model: BK5250
Condition: Used. Comes in non-original packaging. This ethernet coupler is in good condition with minor scuffs and scratches from previous use.
The photos show the exact item(s) the buyer will receive.
Notes: This ethernet coupler was removed from a working system and has not been tested since its removal.
No manuals, cords/cables, or additional items are included if not listed or shown.
Included:
- (1) Beckhoff BK5250 DeviceNet Coupler
- (1) Beckhoff KL1184 Digital Input Module 4x Digital Input 24VDC Negative Switch 3ms
- (4) Beckhoff KM1002-0000 Digital Input Terminals Module
- (2) Beckhoff KL9400 PLC module
- (5) Beckhoff KL2012 2 x digital output
- (4) Beckhoff KL2622 PLC module
- (1) Beckhoff KL1408 Digital Input Terminal 8-Channel
- (1) Beckhoff KL2408 Digital Output Terminal 8-Channel
- (1) Beckhoff KL9010 Bus End Terminal
Specifications:
- Manufacturer: Keckhoff
-
Model: BK5250
- Number of Bus Terminals 64 (255 with K-bus extension)
- Max. number of bytes Fieldbus 512 byte input and 512 byte output
- Digital peripheral signals 1,020 inputs/outputs
- Analog peripheral signals 256 inputs/outputs
- Configuration possibility via KS2000 or the controller
- Data transfer rates automatic detection
- Bus interface 1 x open pluggable connector, 5-pin, included
- Data transfer medium screened, twisted copper wire with power supply, 5-pin
- Power supply 24 V DC (-15 %/+20 %), through bus cable 11…25 V (conforms to DeviceNet specification)
-
Model: KL1184
- Connection technology 2-/3-wire
- Specification ground switching
- Number of inputs 4
- Nominal voltage 24 V DC (-15 %/+20 %)
- “0” signal voltage 18…30 V
- “1” signal voltage 0…7 V
- Input filter type. 3.0 ms
- Input current type. 5 mA
- Current consumption K-bus typ. 8 mA
- Electrical isolation 500 V (K-bus/field potential)
- Bit width in the process image 4 inputs
- Configuration no address or configuration setting
-
Model: KM1002
- Connection technology plug
- Specification EN 61131-2, type 1
- Number of inputs 16 (2 x 8)
- Nominal voltage 24 V DC (-15 %/+20 %)
- “0” signal voltage -3…+5 V
- “1” signal voltage 15…30 V
- Input filter type. 3.0 ms
- Input current type. 5 mA
- Current consumption K-bus Typ. 3 mA
- Current consumption power contacts – (no power contacts)
- Electrical isolation 500 V (K-bus/field potential)
- Bit width in the process image 16 inputs
- Configuration no address or configuration setting
-
Model: KL9400
- Input voltage 24 V DC (-15 %/+20 %)
- Output voltage 5 V DC
- Output current 2 A for K-bus supply
- Power contacts max. 24 V DC/max. 10 A
- Short-circuit proof yes
-
Model: KL2012
- Connection technology 4-wire
- Number of outputs 2
- Nominal voltage 24 V DC (-15 %/+20 %)
- Load type ohmic, inductive, lamp load
- Max. output current 0.5 A (short-circuit proof) per channel
- Short-circuit current < 2 A
- Breaking energy < 150 mJ/channel
- Reverse voltage protection –
- Electrical isolation 500 V (K-bus/field potential)
- Current consumption power contacts type. 15 mA + load
- Current consumption K-bus typ. 5 mA
- Bit width in the process image 2 outputs
- Configuration no address or configuration setting
-
Model: KL2622
- Number of outputs 2 x make contacts
- Nominal voltage 230 V AC/30 V DC
- Load type ohmic, inductive, lamp load
- Max. output current 5 A per channel
- Switching current 5 A AC/DC (ohmic)/2 A AC/DC (inductive)
- Ohmic switching current 5 A AC/DC
- Inductive switching current 2 A AC/DC
- Minimum permitted load 10 mA at 5 V DC
- Lamp test, electronic ballast max. 5 A starting current (4 x 58 W)
- Electrical isolation 500 V (K-bus/field potential)
- Current consumption power contacts –
- Current consumption K-bus Typ. 85 mA
- Bit width in the process image 2 outputs
- Operating cycles mech. (min.) 2 x 107
- Operating cycles are electric. (min.) 1 x 105 (5 A/30 V DC)
- Configuration no address or configuration setting
- Special features potential-free contacts
-
Model: KL1408
- Connection technology 1-wire
- Specification EN 61131-2, type 1/3
- Number of inputs 8
- Nominal voltage 24 V DC (-15 %/+20 %)
- “0” signal voltage -3…+5 V (EN 61131-2, type 1/3)
- “1” signal voltage 11…30 V (EN 61131-2, type 3)
- Input filter type. 3.0 ms
- Input current type. 3 mA (EN 61131-2, type 3)
- Current consumption K-bus typ. 5 mA
- Current consumption power contacts typ. 2 mA + load
- Electrical isolation 500 V (K-bus/field potential)
- Bit width in the process image 8 inputs
- Configuration no address or configuration setting
-
Model: KL2408
- Connection technology 1-wire
- Number of outputs 8
- Nominal voltage 24 V DC (-15 %/+20 %)
- Load type ohmic, inductive, lamp load
- Max. output current 0.5 A (short-circuit proof) per channel
- Short-circuit current < 2 A
- Breaking energy < 150 mJ/channel
- Reverse voltage protection yes
- Electrical isolation 500 V (K-bus/field potential)
- Current consumption power contacts type. 60 mA + load
- Current consumption K-bus Typ. 18 mA
- Bit width in the process image 8 outputs
- Configuration no address or configuration setting
-
Model: KL9010
- Special features end terminal for bus communication
Hassle Free Returns
- DougDeals will pay return shipping if the item needs to be returned for any reason
- Return window is 30 days from delivery date
- See complete terms
CDN Systems LLC, DBA Doug Deals, is not an authorized distributor or affiliated with the manufacturer of this product. Original manufacturer's warranty does not apply.