Manufacturer: Beckhoff

Model: EK1100

Condition: Used. This PLC Assembly is in good cosmetic condition with scuffs and scratches from regular industrial use.  The connection wires were clipped at the front of the module during removal.  Comes in non-original packaging. Cosmetic appearance may vary slightly from pictured unit(s).

Notes: This PLC Assembly was removed from decommissioned equipment and has not been tested. No manuals, cords/cables, or additional items are included if not listed or shown.

Included:

  • (1)  Beckhoff EK1100 EtherCat Extension 1 x RJ45 Socket
  • (1)  Beckhoff EK1110 EtherCat Coupler 2 x RJ45 Socket
  • (2)  Beckhoff EL1809 EtherCat Terminal 16-Channel Digital Input
  • (1)  Beckhoff EL2809 EtherCat Terminal 16-Channel Digital Output
  • (1)  Beckhoff EL6900 EtherCat Terminal Communication Interface TwinSAFE Logic
  • (2)  Beckhoff EL1904 EtherCat Terminal 4-Channel Digital Input TwinSAFE
  • (1)  Beckhoff EL2904 EtherCat Terminal 4-Channel Digital Output TwinSAFE

Specifications:

  • Manufacturer:  Beckhoff
  • Model:  EK1100 / EK1110 / EL1809 / EL2809 / EL6900 / EL1904 / EL2904  
  • Description:  EtherCat PLC I/O Assembly
    • (1)  Beckhoff EK1100 EtherCat Extension 1 x RJ45 Socket
      • Task within EtherCAT system    conversion of the E-bus signals to 100BASE-TX Ethernet for extension of the EtherCAT network
      • Data transfer medium    Ethernet/EtherCAT cable (min. Cat.5), shielded
      • Distance between stations    100 m (100BASE-TX)
      • Protocol    any EtherCAT protocol
      • Delay approx. 1 µs
      • Data transfer rates    100 Mbit/s
      • Configuration    not required
      • Bus interface    1 x RJ45
      • Power supply    from E-bus
      • Current consumption E-bus typ. 130 mA
      • Electrical isolation    500 V (supply voltage/Ethernet)
      • Weight approx. 50 g
      • Operating/storage temperature    -25…+60 °C/-40…+85 °C
      • EMC immunity/emission    conforms to EN 61000-6-2/EN 61000-6-4
      • Relative humidity    95 %, no condensation
      • Vibration/shock resistance    conforms to EN 60068-2-6/EN 60068-2-27
      • Protect. rating/installation pos.    IP20/variable
      • Approvals/markings    CE, UL, ATEX, IECEx
    • (1)  Beckhoff EK1110 EtherCat Coupler 2 x RJ45 Socket
      • Task within EtherCAT system    coupling of EtherCAT Terminals (ELxxxx) to 100BASE-TX EtherCAT networks
      • Data transfer medium    Ethernet/EtherCAT cable (min. Cat.5), shielded
      • Distance between stations max. 100 m (100BASE-TX)
      • Number of EtherCAT Terminals    up to 65,534
      • Protocol    EtherCAT
      • Delay approx. 1 µs
      • Data transfer rates    100 Mbit/s
      • Bus interface    2 x RJ45
      • Power supply    24 V DC (-15 %/+20 %)
      • Current consumption from US    70 mA + (∑ E-bus current/4)
      • Current consumption from UP    load
      • Current supply E-bus    2000 mA
      • Power contacts max. 24 V DC/max. 10 A
      • Electrical isolation    500 V (power contact/supply voltage/Ethernet)
      • Operating/storage temperature    -25…+60 °C/-40…+85 °C
      • EMC immunity/emission    conforms to EN 61000-6-2/EN 61000-6-4
      • Relative humidity    95 %, no condensation
      • Vibration/shock resistance    conforms to EN 60068-2-6/EN 60068-2-27
      • Protect. rating/installation pos.    IP20/variable
      • Approvals/markings    CE, UL, ATEX, IECEx, DNV GL, cFMus
    • (2)  Beckhoff 1809 EtherCat Terminal 16-Channel Digital Input
      • Connection technology    1-wire
      • The specification EN 61131-2, type 1/3
      • Number of inputs    16
      • Nominal voltage    24 V DC (-15 %/+20 %)
      • “0” signal voltage    -3…+5 V (EN 61131-2, type 1/3)
      • “1” signal voltage    11…30 V (EN 61131-2, type 3)
      • Input current type. 3 mA (EN 61131-2, type 3)
      • Input filter type. 3.0 ms
      • Distributed clocks    –
      • Current consumption power contacts    typ. 4 mA + load
      • Current consumption E-bus type. 100 mA
      • Electrical isolation    500 V (E-bus/field potential)
      • Configuration    no address or configuration setting
      • Special features    standard terminal with a high number of channels for slow 24 V DC edges, a direct plug-in technique
      • Weight approx. 65 g
      • Operating/storage temperature    -25…+60 °C/-40…+85 °C
      • Relative humidity    95 %, no condensation
      • Vibration/shock resistance    conforms to EN 60068-2-6/EN 60068-2-27
      • EMC immunity/emission    conforms to EN 61000-6-2/EN 61000-6-4
      • Protect. rating/installation pos.    IP20/variable (see documentation)
      • Approvals/markings    CE, UL, ATEX, IECEx
    • (1)  Beckhoff EL2809 EtherCat Terminal 16-Channel Digital Output
      • Connection technology    1-wire
      • Number of outputs    16
      • Nominal voltage    24 V DC (-15 %/+20 %)
      • Load type    ohmic, inductive, lamp load
      • Distributed clocks    –
      • Max. output current    0.5 A (short-circuit proof) per channel
      • Short-circuit current type. < 2 A
      • Reverse voltage protection    yes
      • Breaking energy    < 150 mJ/channel
      • Switching times type. TON: 60 µs, typ. TOFF: 300 µs
      • Current consumption E-bus type. 140 mA
      • Electrical isolation    500 V (E-bus/field potential)
      • Current consumption power contacts type. 35 mA + load
      • Bit width in the process image    16 outputs
      • Configuration    no address or configuration setting
      • Weight approx. 70 g
      • Operating/storage temperature    -25…+60 °C/-40…+85 °C
      • Relative humidity    95 %, no condensation
      • Vibration/shock resistance    conforms to EN 60068-2-6/EN 60068-2-27
      • EMC immunity/emission    conforms to EN 61000-6-2/EN 61000-6-4
      • Protect. rating/installation pos.    IP20/variable
      • Approvals/markings    CE, UL, ATEX, IECEx, DNV GL, cFMus
    • (1)  Beckhoff EL6900 EtherCat Terminal Communication Interface TwinSAFE Logic
      • Specification    link unit between safe input and output signals
      • Protocol    TwinSAFE/Safety over EtherCAT
      • Cycle time approx. 500 µs/according to project size
      • Fault response time    ≤ watchdog time (parameterizable)
      • Current consumption power contacts    –
      • Current consumption E-bus typ. 188 mA
      • Installation position    horizontal
      • Safety standard    DIN EN ISO 13849-1:2008 (Cat. 4, PL e) and EN 61508:2010 (SIL 3)
      • Weight approx. 50 g
      • IP protection rating    IP20
    • (2)  Beckhoff EL1904 EtherCat Terminal 4-Channel Digital Input TwinSAFE
      • Connection technology    1-/2-wire
      • Number of inputs    4
      • Protocol    TwinSAFE/Safety over EtherCAT
      • Response time    typ. 4 ms (read input/write to E-bus)
      • Fault response time    ≤ watchdog time (parameterizable)
      • For current consumption power contacts    see the documentation
      • Current consumption E-bus type. 200 mA
      • Installation position    horizontal
      • Safety standard    DIN EN ISO 13849-1:2008 (Cat. 4, PL e) and EN 61508:2010 (SIL 3)
      • Weight approx. 50 g
      • IP protection rating    IP20
    • (1)  Beckhoff EL2904 EtherCat Terminal 4-Channel Digital Output TwinSAFE
      • Connection technology    1-/2-wire
      • Specification    output of output signals
      • Number of outputs    4
      • Max. output current    0.5 A (per channel), min. 20 mA (with active current measurement)
      • Protocol    TwinSAFE/Safety over EtherCAT
      • Fault response time    ≤ watchdog time (parameterizable)
      • Current consumption power contacts    load-dependent
      • Current consumption E-bus typ. 221 mA
      • Installation position    horizontal
      • Safety standard    DIN EN ISO 13849-1:2008 (Cat. 4, PL e) and EN 61508:2010 (SIL 3)
      • Weight approx. 100 g
      • IP protection rating    IP20


Hassle Free Returns

  • DougDeals will pay return shipping if the item needs to be returned for any reason
  • Return window is 30 days from delivery date
  • See complete terms

CDN Systems LLC, DBA Doug Deals, is not an authorized distributor or affiliated with the manufacturer of this product. Original manufacturer's warranty does not apply.

View AllClose

Additional Information

Condition:
Used
View AllClose