Keyence FS-V1 Photoelectric Fiberoptic Amplifier w/ 2x PS-T2 and 1x FS-T2

SKU:
X19S017
Shipping:
Free Shipping
  • Keyence FS-V1 Photoelectric Fiberoptic Amplifier w/ 2x PS-T2 and 1x FS-T2
  • Keyence FS-V1 Photoelectric Fiberoptic Amplifier w/ 2x PS-T2 and 1x FS-T2
$39.99

Description

Manufacturer: Keyence

Model: FS-V1

Condition: Used. Comes in non-original packaging. These modules are in good condition with minor scuffs and scratches from previous use. Cosmetic appearance may vary slightly from pictured unit(s).

Notes: These items were removed from a working environment and have not been tested since their removal. No manuals, cords/cables, or additional items are included if not listed or shown.

Included:

  • (1) Keyence FS-V1 Photoelectric Fiberoptic Amplifier w/ 2x PS-T2 and 1x FS-T2

Specifications:

  • Manufacturer: Keyence
  • Model FS-V1
  • Description: Fiber Amplifier
    • Type Main unit
    • Output NPN
    • Light source Red LED
    • Response time 250 µs
    • Operation mode LIGHT-ON/DARK-ON (switch-selectable)
    • Indicator lamp
    • Display indicator (Two): Red LED
    • Received light display: LCD
    • (Two color display: Red and green)
    • Calibration indicator: Orange LED
    • Timer function ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)
    • Control output NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max. The FS-V1P is equipped with two outputs.
    • Protection circuit Reversed polarity protection, over-current protection, surge absorber
    • Unit expansion Up to 16 expansion units can be connected (a total of 17 units).*1
    • Mutual interference suppression 4
  • Model FS-T2
  • Type 1-line expansion unit
    • Output NPN
    • Light source Red LED
    • Sensitivity adjustment/Mode selection Button
    • Response time 250 µs
    • Operation mode LIGHT-ON/DARK-ON (switch-selectable)
    • Indicator lamp Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED
    • Timer function ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)
    • Input Non-voltage input (contact, solid state)
    • Control output NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.
    • Stability output NPN open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max. *1
    • Protection circuit Reversed polarity protection, over-current protection, surge absorber
    • Unit expansion Up to 16 expansion units can be connected (a total of 17 units).*2
    • Mutual interference suppression 4
  • Model PS-T2
  • Type 1-line connection
    • Output NPN
    • Response time 500 µs
    • Operation mode LIGHT-ON/DARK-ON (switch-selectable)
    • Indicator lamp Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Yellow LED
    • Timer function ON-delay: 40 ms, OFF-delay: 40 ms, Timer OFF (switch-selectable)
    • External calibration input signal Non-voltage input (contact, solid state)
    • Control output NPN:100 mA max. (40 V max.) Residual voltage: 1 V max.
    • Stability output NPN:50 mA max. (40 V max.) Residual voltage: 1 V max. *1
    • Protection circuit Reverse polarity protection, Over-current protection, Surge absorber
    • Multiple connections to expansion units Up to 16 expansion units can be connected (a total of 17 units)


Hassle Free Returns

  • DougDeals will pay return shipping if the item needs to be returned for any reason
  • Return window is 30 days from delivery date
  • See complete terms

CDN Systems LLC, DBA Doug Deals, is not an authorized distributor or affiliated with the manufacturer of this product. Original manufacturer's warranty does not apply.

View AllClose

Additional Information

Condition:
Used
View AllClose