Description
Manufacturer: MKS
Model: DLT2A2-33196
Condition: New Other. Comes in non-original packaging. The bag has been opened and the unit has some scratching on the top and bottom from installation and use, but the unit is sealed and in good condition.
Cosmetic appearance may vary slightly from pictured unit(s).
Notes: No manuals, cords/cables, or additional items are included if not listed or shown.
Included:
- (1) MKS DLT2A2-33196 Delta II 2-Zone FRC Flow Ratio Controller 2000 SCCM N2 DNet
Specifications:
- Manufacturer: MKS
- Model: DLT2A2-33196
-
Description: Flow Ratio Controller
- Full-Scale Ranges 2000 sccm
- Maximum Operating Outlet Pressure 200 Torr
- Maximum Allowable Outlet Pressure Differential 50 Torr (between Q1 and Q2)
- Normal Operating Pressure Differential (N2) <150 Torr (<450 Torr for 10000/10000)
- Proof Pressure 1000 psig
- Burst Pressure 1500 psig
- Input Flow Range (N2 equivalent) 5 to 100% of each channel Full Scale rating
- Ratio Control Range 1:1 to 20:1 and 20:1 to 1:1
- Ratio Accuracy ±2% of ratio set point
- Ratio Repeatability & Reproducibility 0.3% of ratio set point
- Resolution 0.02% of channel Full Scale
-
Temperature Coefficient (per channel):
- Zero 0.05% Full Scale/°C
- Span 0.08% Reading/°C
- Ratio Settling Time <2 seconds
- Warm-Up Time 30 minutes
- Storage Temperature -20 to 65°C
- Storage Humidity 0 to 95% relative humidity, non-condensing
- Temperature Display 0 to 100°C
- Temperature Readout Units °C
- Temperature Accuracy ±2°C
- Temperature Resolution 0.1°C
- Mounting Style: Inline
- Input Port: 1/4" Male VCR
- Output Port 1: 1/4" Male VCR
- Output Port 2: 1/4" Male VCR
Hassle Free Returns
- DougDeals will pay return shipping if the item needs to be returned for any reason
- Return window is 30 days from delivery date
- See complete terms
CDN Systems LLC, DBA Doug Deals, is not an authorized distributor or affiliated with the manufacturer of this product. Original manufacturer's warranty does not apply.