Schneider Electric LUB32 25HP Power Base Starter w/ LUCA18FU TeSys Control Unit

SKU:
X33H003
Shipping:
Calculated at Checkout
  • Schneider Electric LUB32 25HP Power Base Starter w/ LUCA18FU TeSys Control Unit
  • Schneider Electric LUB32 25HP Power Base Starter w/ LUCA18FU TeSys Control Unit
  • Schneider Electric LUB32 25HP Power Base Starter w/ LUCA18FU TeSys Control Unit
  • Schneider Electric LUB32 25HP Power Base Starter w/ LUCA18FU TeSys Control Unit
$119.99

Description

Manufacturer: Schneider Electric

Model: LUB32

Condition: Used. This Motor Starter is in good cosmetic condition with scuffs, scratches, and dust from regular industrial use and comes in non-original packaging.  There is also "FAN" written in permanent ink on the front of the controller in our inventory and "5" on the other in inventory.
Cosmetic appearance may vary slightly from pictured unit(s).

Notes: This Motor Starter was removed from decommissioned equipment and has not been tested.
No manuals, cords/cables, or additional items are included if not listed or shown.

Included:

  • (1)  Schneider Electric LUB32 25HP Power Base Starter w/ LUCA18FU TeSys Control Unit

Specifications:

  • Schneider Electric
  • Model:  LUB32 / LUCA18FU
  • Description:  Power Base Starter w/  TeSys Control Unit
    • Power Base
      • Range
        • TeSys
      • Product name
        • TeSys Ultra
      • device short name
        • LUB
      • Product or Component Type
        • Non-reversing power base
      • Device Application
        • Motor control
        • Motor protection
      • Poles description
        • 3P
      • Suitability for isolation
        • Yes
      • [Ue] rated operational voltage
        • 690 V AC power circuit
      • Network frequency
        • 40...60 Hz
      • [Ith] conventional free air thermal current
        • 32 A
      • [Ie] rated operational current
        • 28.5 A <= 440 V
        • 23 A 500 V
        • 21 A 690 V
      • Utilization category
        • AC-43
        • AC-44
        • AC-41
      • [Ics] rated service-breaking capacity
        • 50 kA 230 V
        • 50 kA 440 V
        • 10 kA 500 V
        • 4 kA 690 V
      • Auxiliary contact composition
        • 1 NO + 1 NC
      • Auxiliary contacts type
        • Linked contacts 1 NO + 1 NC) IEC 60947-4-1
        • Mirror contact 1 NC) IEC 60947-1
      • [Uc] control circuit voltage
        • 24 V AC 50/60 Hz
        • 24 V DC
        • 48...72 V AC 50/60 Hz
        • 48...72 V DC
        • 110...240 V AC 50/60 Hz
        • 110...220 V DC
      • Typical current consumption
        • 200 mA 24 V DC I maximum while closing with LUCM
        • 220 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
        • 220 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
        • 25 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
        • 25 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
        • 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
        • 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
        • 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
        • 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
        • 45 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
        • 45 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
        • 75 mA 24 V DC I rms sealed with LUCM
        • 80 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
        • 90 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
      • Heat dissipation
        • 3 W control circuit with LUCA, LUCB, LUCC, LUCD
        • 1.8 W control circuit with LUCM
      • safety reliability level
        • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
        • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
      • Operating time
        • 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit
        • 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit
        • 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit
        • 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit
        • 65 ms closing with LUCM control circuit
      • Mechanical durability
        • 15 Mcycles
      • Maximum operating rate
        • 3600 cyc/h
      • Product Certifications
        • CE
        • UL
        • CSA
        • CCC
        • EAC
        • ASEFA
        • ATEX
        • Marine
      • Standards
        • EN 60947-6-2
        • IEC 60947-6-2
        • UL 60947-4-1, with phase barrier
        • CSA C22.2 No 60947-4-1, with phase barrier
      • [Ui] rated insulation voltage
        • 690 V IEC 60947-6-2 3)
        • 600 V UL 60947-4-1
        • 600 V CSA C22.2 No 60947-4-1
      • [Uimp] rated impulse withstand voltage
        • 6 kV IEC 60947-6-2
      • Safe separation of circuit
        • 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N
        • 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
      • Fixing mode
        • Clipped DIN rail)
        • Screw-fixed plate)
      • Connections - terminals
        • Control circuit screw clamp terminals 1 0.00…0.00 in² (0.34…1.5 mm²) flexible with cable end
        • Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) flexible without cable end
        • Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) rigid
        • Control circuit screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²) flexible with cable end
        • Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) flexible without cable end
        • Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) rigid
        • Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²) rigid
        • Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) flexible with cable end
        • Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²) flexible without cable end
        • Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) flexible with cable end
        • Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) rigid
        • Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) flexible without cable end
      • Tightening torque
        • Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) flat 0.20 in (5 mm)
        • Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) Philips no 1 0.20 in (5 mm)
        • Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) flat 0.24 in (6 mm)
        • Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) Philips No 2 0.24 in (6 mm)
        • Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) pozidriv No 2 0.24 in (6 mm)
        • Width
        • 1.77 in (45 mm)
      • Height
        • 6.06 in (154 mm)
      • Depth
        • 4.96 in (126 mm)
      • Product Weight
        • 1.98 lb(US) (0.9 kg)
      • Compatibility code
        • LUB
      • IP degree of protection
        • IP20 IEC 60947-1 front panel and wired terminals)
        • IP20 IEC 60947-1 other face)
        • IP40 IEC 60947-1 front panel outside connection zone)
      • Protective treatment
        • TH IEC 60068
      • Ambient air temperature for operation
      • -13…140 °F (-25…60 °C) with LUCM
      • -13…158 °F (-25…70 °C) with LUCA, LUCB, LUCC, LUCD
      • Ambient Air Temperature for Storage
      • -40…185 °F (-40…85 °C)
      • Fire resistance
      • 1760 °F (960 °C) parts supporting live components IEC 60695-2-12
      • 1202 °F (650 °C) IEC 60695-2-12
      • Operating altitude
      • 6561.68 ft (2000 m)
      • Shock resistance
      • 10 gn power poles open IEC 60068-2-27
      • 15 gn power poles closed IEC 60068-2-27
      • Vibration resistance
      • 2 gn 5…300 Hz) power poles open IEC 60068-2-27
      • 4 gn 5…300 Hz) power poles closed IEC 60068-2-27
      • Resistance to electrostatic discharge
      • 8 kV 3 in open air IEC 61000-4-2
      • 8 kV 4 on contact IEC 61000-4-2
      • Resistance to radiated fields
      • 9.14 V/m (10 V/m) 3 IEC 61000-4-3
      • Resistance to fast transients
      • 2 kV 3 serial link IEC 61000-4-4
      • 4 kV 4 all circuits except for serial link IEC 61000-4-4
      • Non-dissipating shock wave
      • 1 kV serial mode 24...240 V AC IEC 60947-6-2
      • 1 kV serial mode 48...220 V DC IEC 60947-6-2
      • 2 kV common mode 24...240 V AC IEC 60947-6-2
      • 2 kV common mode 48...220 V DC IEC 60947-6-2
      • Immunity to radioelectric fields
      • 10 V IEC 61000-4-6
      • Immunity to microbreaks
      • 3 ms control circuit
      • Immunity to voltage dips
      • 70 % / 500 ms IEC 61000-4-11
    • Control Unit
      • Range
        • TeSys
      • Range of Product
        • TeSys Ultra
      • Product name
        • TeSys Ultra
      • device short name
        • LUCA
      • Product or Component Type
        • Standard control unit
      • Device Application
        • Motor control
        • Motor protection
      • Product Specific Application
        • Basic protection requirements for motor starters: overload and short-circuit
      • main function available
        • Earth fault protection
      • Manual reset
        • Protection against phase failure and phase imbalance
        • Protection against overload and short-circuit
      • Product Compatibility
        • Power base LUB32
        • Power base LUB38
        • Power base LUB320
        • Power base LUB380
        • Reversing contactor breaker LU2B32FU
        • Reversing contactor breaker LU2B38FU
      • [Ue] rated operational voltage
        • 690 V AC
      • Network frequency
        • 40...60 Hz
      • Load type
        • 3-phase motor self-cooled
      • Utilization category
        • AC-41
        • AC-44
        • AC-43
      • Motor power kW
        • 7.5 kW 400...440 V AC 50/60 Hz
        • 9 kW 500 V AC 50/60 Hz
        • 15 kW 690 V AC 50/60 Hz
      • rated motor current adjustment range
        • 4.5…18 A
      • Thermal overload class
        • Class 10 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2
        • Class 10 40…60 Hz -13…158 °F (-25…70 °C) UL 508
      • Tripping threshold
        • 14.2 x Ir +/- 20 %
      • Phase failure sensitivity
        • Yes
      • [Uc] control circuit voltage
        • 110...240 V AC
        • 110...220 V DC
      • Control circuit voltage limits
        • 88...264 V AC 110...240 V in operation
        • 88...242 V DC 110...220 V in operation
        • 55 V AC 110...240 V drop-out
        • 55 V DC 110...220 V drop-out
      • Typical current consumption
        • 280 mA 110...240 V AC I maximum while closing with LUB32
        • 280 mA 110...240 V AC I maximum while closing with LUB38
        • 280 mA 110...220 V DC I maximum while closing with LUB32
        • 280 mA 110...220 V DC I maximum while closing with LUB38
        • 25 mA 110...240 V AC I rms sealed with LUB32
        • 25 mA 110...240 V AC I rms sealed with LUB38
        • 25 mA 110...220 V DC I rms sealed with LUB32
        • 25 mA 110...220 V DC I rms sealed with LUB38
      • Heat dissipation
        • 3 W control circuit with LUB32
        • 3 W control circuit with LUB38
      • Operating time
        • 35 ms opening with LUB32 control circuit
        • 35 ms opening with LUB38 control circuit
        • 50 ms closing with LUB32 control circuit
        • 50 ms closing with LUB38 control circuit
      • Standards
        • EN 60947-6-2
        • IEC 60947-6-2
        • UL 60947-4-1, with phase barrier
        • CSA C22.2 No 60947-4-1, with phase barrier
        • Product Certifications
        • CE
        • UL
        • CSA
        • CCC
        • EAC
        • ASEFA
        • ATEX
        • Marine
      • [Ui] rated insulation voltage
        • 690 V IEC 60947-6-2
        • 600 V UL 60947-4-1
        • 600 V CSA C22.2 No 60947-4-1
        • [Uimp] rated impulse withstand voltage
        • 6 kV IEC 60947-6-2
      • Safe separation of circuit
        • 400 V SELV between the control and auxiliary circuits IEC 60947-1
        • 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
      • Fixing mode
        • Plug-in front face)
      • Width
        • 1.77 in (45 mm)
      • Height
        • 2.60 in (66 mm)
      • Depth
        • 2.36 in (60 mm)
      • Product Weight
        • 0.30 lb(US) (0.135 kg)
      • Compatibility code
        • LUCA
      • Environment
        • IP degree of protection
        • IP20 front panel and wired terminals IEC 60947-1
        • IP20 other faces IEC 60947-1
        • IP40 front panel outside connection zone IEC 60947-1
      • Protective treatment
        • TH IEC 60068
      • Ambient air temperature for operation
        • -13…158 °F (-25…70 °C)
      • Ambient Air Temperature for Storage
        • -40…185 °F (-40…85 °C)
      • Operating altitude
        • 6561.68 ft (2000 m)
      • Fire resistance
        • 1760 °F (960 °C) parts supporting live components IEC 60695-2-12
        • 1202 °F (650 °C) IEC 60695-2-12
      • Shock resistance
        • 10 gn power poles open IEC 60068-2-27
        • 15 gn power poles closed IEC 60068-2-27
      • Vibration resistance
        • 2 gn 5…300 Hz power poles open IEC 60068-2-6
        • 4 gn 5…300 Hz power poles closed IEC 60068-2-6
      • Resistance to electrostatic discharge
        • 8 kV 3 in open air IEC 61000-4-2
        • 8 kV 4 on contact IEC 61000-4-2
      • Non-dissipating shock wave
        • 1 kV serial mode IEC 60947-6-2
        • 2 kV common mode IEC 60947-6-2
      • Resistance to radiated fields
        • 9.14 V/m (10 V/m) 3 IEC 61000-4-3
      • Resistance to fast transients
        • 2 kV 3 serial link IEC 61000-4-4
        • 4 kV 4 all circuits except for serial link IEC 61000-4-4
      • Immunity to radioelectric fields
        • 10 V IEC 61000-4-6
      • Immunity to microbreaks
        • 3 ms
      • Immunity to voltage dips
        • 70 % / 500 ms IEC 61000-4-11


Hassle Free Returns

  • DougDeals will pay return shipping if the item needs to be returned for any reason
  • Return window is 30 days from delivery date
  • See complete terms

CDN Systems LLC, DBA Doug Deals, is not an authorized distributor or affiliated with the manufacturer of this product. Original manufacturer's warranty does not apply.

View AllClose

Additional Information

Condition:
Used
View AllClose